FROST PROTECTION AGAINST ICE AND LOW TEMPERATURE MAINTENANCE FOR PIPE, TANK, RECEPTACLES, VALVES, GUTTERS…
 By using our tracers TRACECO® type, you ensure the best heat-tracing system. They are designed to prevent any risk of burst pipes due to freezing. Self Limiting or Self Regulating Technology allows easy operation safely. The power changes depending on the temperature and prevents overheating. When it is cold, the polymer shrinks and facilitates the flow of current, thereby increasing the temperature of the cable. As it gets warmer, the polymer expands and prevents the current: the Self Regulating cable heats less than before. Finally, a « parallel » technology allows the cable to be cut to desired length directly on the site. Exact fit the length of heating cable for your needs. The CableBox storage system on coil allows easy handling, quick and convenient. This product is in stock and can be used with the fast connector system DomoClick®
HEATING CABLE DESCRIPTION
Bus wire Cu nickel-plated (2 x 0.55mm²) Self limiting heating element Insultation Tin-plated copper protective earth wires with Protective aluminium foil Thermoplastique (TPE-O) outer jacket (Black)
Reference Désignation Power Dimension (naked) Dimension TRACECO-15 TRACECO ESR-S-15-AO 12 W/m àat10°C 6,40 x 3,80 (mm) 7,30 x 5,10 (mm)
HEATING CABLE DATASHEET
Nominal Voltage 230V
Maximum length circuit: TRACECO-15…………. 110 m Tolerances -0/+5 W Maximum exposure temperature (energised) 65°C Maximum exposure temperature (deenergised) 80°C Temperature Class T6 Minimum Bending Radius 27 mm Minimum installation temperature -35°C
Weight approx (alufoil) 66 kg/km
Weight approx (Braided) 72 kg/km CERTIFICATION     CSTB, ATEX, VDE, GOST-R, FIMKO, CE
CIRCUIT LENGTH*
*Maximum Circuit lengths with ELCB curve C The protection of each circuit shall be in accordance with NF C 15-100. The protection of persons is ensured by a residual current of 30 mA maximum for each 7.5 kilowatts maximum. The heaters are supplied at 230 volts.
PACKAGING Standard length on rolls : 500m / CableBox® : 100m
MARQUAGE Tous les câbles autorégulants ELTRACE sont marqués afin d'assurer la traçabilité du produit.
INSTALLATION Les câbles autorégulants ELTRACE doivent être installés suivant les normes en vigueur au jour de l’installation (cahier des prescriptions techniques communes de mise en œuvre du CSTB, NF C 15-100, VDE…) pour les points où elles s'appliquent, ainsi que les préconisations d'utilisation.
Last Updated on Tuesday, 03 May 2011 19:41
SELF LIMITING HEATING CABLE
ESR®-S - Food Compatibility
FOR FROST PROTECTION INSIDE PIPE
Self-regulating heating cables ESR-S-BOA have been developed to meet standards food. You can safely place them inside the pipes. They allow you prevent freezing and the risk of bursting pipes. The parallel technology "self regulating" allows easy operation safely. Self-regulated power cable varies with the ambient temperature and prevents overheating. When it's cold the polymer shrinks and facilitates the flow of current, thereby increasing the temperature cable. As it gets warmer, the polymer expands and prevents the passage of current: the cable cooler. Finally,with a technology called "parallel" you can cut the heating cables directly to the desired length on the site, to precisely fit the length of heating cable for your needs. The storage system on coil type Cablebox ® allows easy handling, quick and convenient.
DESCRIPTION
Bus wire Cu nickel-plated (2 x 0.55mm²) Self limiting heating element Insultation Tin-plated copper protective earth wires with Protective aluminium foil Food compatibility outer jacket
Référence Désignation Puissance Section totale ESR-S-BOA-10 Self Limiting Cable Food Compatibility 10 W/m à 10°C 7,6 x 5,2 (mm) ESR-S-BOA-15 Self Limiting Cable Food Compatibility 15 W/m à 10°C 7,6 x 5,2 (mm) ESR-S-BOA-18 Self Limiting Cable Food Compatibility 18 W/m à 10°C 7,6 x 5,2 (mm)
DATASHEET
Nominal Voltage 230V Maximum length circuit: Tolerances -0/+5 W ESR-S-BOA-10…………. 100 m Maximum exposure temperature (energised) 65°C ESR-S-BOA-15…………. 72 m Maximum exposure temperature (deenergised) 65°C ESR-S-BOA-18…………. 60 m Minimum Bending Radius 35 mm Minimum installation temperature -35°C
CERTIFICATION
CSTB, ATEX, VDE, GOST-R, FIMKO, CE
CIRCUIT LENGTH*
DESIGNATION STARTING TEMPERATURE (°C) 10 A ESR-S-10-BOA 10°C 100 / 60** ESR-S-10-BOA 0°C 95 ESR-S-10-BOA -20°C 77 ESR-S-15-BOA 10°C 72 ESR-S-15-BOA 0°C 66 ESR-S-15-BOA -20°C 52 ESR-S-18-BOA 10°C 60 ESR-S-18-BOA 0°C 58 ESR-S-18-BOA -20°C 41 *Maximum Circuit lengths with ELCB curve C The protection of each circuit shall be in accordance with NF C 15-100. The protection of persons is ensured by a residual current of 30 mA maximum for each 7.5 kilowatts maximum. The heaters are supplied at 230 volts.
PACKING Standard length stored on reel: 500m / CableBox® : 100m
PRINTING All cables are printed in order to ensure the product tracability.
INSTALLATION ELTRACE self-regulating cables must be installed according to standards prevailing at the date of installation (technical requirements specification for implementation of NF C 15-100, VDE ...) where they apply, and the recommendations of use.
ADDITIONAL PRODUCTS Reference Non-ATEX ATEX Connexion Domoclick® ELKSR-1, ELKSR ELKSR-1-e ELKSR-1-d Junction Boxes ELBE-3, ELBE-6, ELBE-8, ELBE-10 ELBA-5-e, ELBA-6-e ELBA-4-d, ELBA-6-d Pipe bracket ELSP-x, ELSP-P1/F, ELSP-P2/F ELSP-2, ELSP-3, ELSP-4, ELSP-5, ELSP-PU Thermostats ELTE-x, ELTH-A2, ELTH-A3, ELTH-A4 ELTH-Athf-Ex ELBSTW Fixing tape ELAA ELTV ELAA ELTV Heat Lagging Output ELSC, ELSC-E ELSC-E Adhesive Label ELET ELET
 
Last Updated on Tuesday, 03 May 2011 19:45
CÂBLES CHAUFFANTS AUTORÉGULANTS EAU-CHAUDE
Câble chauffant électrique TRACECO®-W
Télécharger la fiche technique du câble chauffant autorégulant électrique TRACECO-W
POUR LE MAINTIEN EN MOYENNE TEMPÉRATURE OU POUR LUTTER CONTRE LES RISQUES DE LÉGIONELLOSE DE VOS TUYAUTERIES, RÉSEAU EAU CHAUDE SANITAIRE, EAU USÉE GRASSE, RÉSERVOIRS, CHÉNEAUX, VANNES,..
En utilisant nos traceurs type TRACECO® vous vous assurez du meilleur système de traçage électrique. Ils sont conçus pour maintenir les réseaux d'eau chaude sanitaire à température et lutter contre les risques de légionellose. La technologie "autorégulante" permet une utilisation simple en toute sécurité. La puissance autorégulée des câbles varie en fonction de la température environnante et interdit toute surchauffe. Lorsqu’il fait froid, le polymère se contracte et facilite le passage du courant ce qui permet une augmentation de la température du câble. Et plus il fait chaud, plus le polymère se dilate et empêche le passage du courant, par conséquent le câble chauffe moins. Enfin, la technologie dite « parallèle » permet de couper les câbles chauffants à la longueur souhaitée directement sur le site, afin d’adapter avec précision la longueur du câble chauffant à vos besoins. Son système de stockage sur bobine type CABLEBOX® permet une manipulation simple, rapide et pratique. Ce produit est disponible en stock et utilisable avec le système de raccordement rapide DOMOCLICK®
DESCRIPTION
1- Conducteurs formés de 2 torons de cuivre nickelé composés de 19 fils de 0,287mm de diamètre et de section 1.23mm² 2- Matrice semi-conductrice réticulée par irradiation 3- Isolant polyoléfine Gris 4- Blindage par tresse en cuivre étamé ou par ruban aluminium + drain 5- Gaine Thermoplastique Grise
   
Last Updated on Tuesday, 03 May 2011 19:52
Read more...
Self Limiting Heating Cable
ESR®-R

To Protect Sliding Doors and Opening Doors From Freezing Up - Special Cold Room
By using our self-regulating electric heat tracing ESR-R, you make sure that you get the best defrosting system for negative cold room door.
Through its unique "self regulating" matrix, it is easier and safer to use. you freed from the problems of door sizes.
A single cable replaces all your references, all you resistances, whatever the length of the doors.
Furthermore, the self-regulating heating cable is varying according to its temperature. This avoid overheating especially at the corners of doors (no dysfunction).
Finally, thanks to his "Self limiting" technology called "parallel". You can connect the heating cable ESR-R to the exact length you want. Also you can connect directly into the junction box. Then you do not have to prepare any cold end and thus saving time and substantial cost.
Its storage system on coil type CableBox or bobbins allows easy handling, quick and convenient. This product is available on stock.
DESCRIPTION DES CORDONS CHAUFFANTS
1. Bus wire Cu nickel-plated (2x0.55mm²) 19 x 0,287 mm
2. Self limiting heating element (matrix)
3. Insultation (polyolefine)
Référence Désignation power at 0°C Section ESR-R-30 ESR-R-30 27 W/m at 0°C 6,10 x 5,60 (mm) ESR-R-40 ESR-R-40 38 W/m at 0°C 6,10 x 5,60 (mm)
Datasheet
Nominal Voltage 230V Tolerances -0/+5 W Maximum exposure temperature (energised) 50°C Maximum exposure temperature (deenergised) 55°C Minimum Bending Radius 30 mm Minimum installation temperature -35°C Weight approx. 41,5 kg/km
Maximum length circuit: ESR-R-30…………. 110 m ESR-R-40…………. 110 m

Last Updated on Tuesday, 03 May 2011 19:49
|
SELF LIMITING HEATING CABLE

ESR®-BOT
The ESR-BOT tape is a self-limiting heating tape for applications for general protection against freezing in pipes. An additional layer connected to the heating element (bonded jacket) increases the effect of the electrical insulation and provides additional protection against moisture.
Fluoropolymer is used as an outer jacket, this material offers increased protection against chemicals
and abrasion. Fluoropolymers are also UV-resistant.
When it is cold, the polymer shrinks and facilitates the flow of current, thereby increasing the temperature of the cable. As it gets warmer, the polymer expands and prevents the current: the Self Regulating cable heats less than before.
Finally, a « parallel » technology allows the cable to be cut to desired length directly on the site. Exact fit the length of heating cable for your needs.
The CableBox storage system on coil allows easy handling, quick and convenient. This product is in stock and can be used with the fast connector system DomoClick®
DESCRIPTION

Bus wire Cu nickel-plated (2x1.25mm²)
Self limiting heating element, Matrix
Insulation
Braid
Fluoropolymer overjacket
Reference Designation Power Dimension
ESR-10-BOT ESR-2-BOT-10 10 W/m at 10°C 11,50 x 5,50 (mm)
ESR-15-BOT ESR-2-BOT-15 15 W/m at 10°C 11,50 x 5,50 (mm)
ESR-20-BOT ESR-2-BOT-20 20 W/m at 10°C 11,50 x 5,50 (mm)
ESR-25-BOT ESR-2-BOT-25 25 W/m at 10°C 11,50 x 5,50 (mm)
ESR-30-BOT ESR-2-BOT-33 33 W/m at 10°C 11,50 x 5,50 (mm)
DATASHEET
Nominal Voltage 230V Maximum length circuit:
Tolerances -0/+5 W ESR-10-BOT…………. 205 m
Maximum exposure temperature (energised) 65°C ESR-15-BOT…………. 160 m
Maximum exposure temperature (deenergised) 80°C ESR-20-BOT…………. 140 m
Temperature Class T6 (T5 for 33W/m) ESR-25-BOT…………. 130 m
Minimum Bending Radius 25 mm ESR-30-BOT…………. 110 m
Minimum installation temperature -35°C Weight approx 119kg/km
CERTIFICATION
CSTB, ATEX, VDE, GOST-R, CE
CIRCUIT LENGTH*
*Maximum Circuit lengths with ELCB curve C
The protection of each circuit shall be in accordance with NF C 15-100. The protection of persons is ensured by a residual current of 30 mA maximum for each 7.5 kilowatts maximum. The heaters are supplied at 230 volts.
PACKING
Standard length stored on reel: 500m / CableBox® : 100m
PRINTING
All cables are printed in order to ensure the product tracability.
INSTALLATION
ELTRACE self-regulating cables must be installed according to standards prevailing at the date of installation (technical requirements specification for implementation of NF C 15-100, VDE ...) where they apply,
ADDITIONAL PRODUCTS
Last Updated on Tuesday, 03 May 2011 19:43
Self Limiting Heating Cable
GELTRACE®-PROTIGEL
FROST PROTECTING TAPE IS A RELIABLE AND ECONOMICAL SOLUTION TO YOUR PROBLEMS OF FROST PROTECTION

Applications:
GELTRACE® range is used for the frost protection of pipes. In the protigel®+ version, the thermostat automatically switches on the tape when the temperature falls under +5°C. It enables substantial energy savings and offers in complement the advantages and the safety of a self-regulating tape.
Avoids drainings and permanent use of hydraulic networks. Easy to implement. Available on stock.
Adjustable length according to the network size. Tape finished and controlled in the factory.
No overheating risk thanks to its self regulating system.
When it is cold, the polymer shrinks and facilitates the flow of current, thereby increasing the temperature of the cable. As it gets warmer, the polymer expands and prevents the current: the Self Regulating cable heats less than before.
Finally, a « parallel » technology allows the cable to be cut to desired length directly on the site. Exact fit the length of heating cable for your needs.
Description
1. Bus wire Cu nickel-plated (2 x 0.55mm²)
2. Self limiting heating element
3. Insultation
4. Tin-plated copper protective earth wires with Protective aluminium foil
5. Thermoplastique (TPE-O) outer jacket (Black)
6. Thermostat 5°C
7. Cold lead (1m 3x1.5mm²)
Reference Designation Power GELTRACE-1 Self Limiting cable, 1m lenght, with 5°C thermostat and 1m cold lead 15 W at 10°C GELTRACE-xx Self Limiting cable, 1m to 35m lenght, with 5°C thermostat, 1m cold lead 15 W/m at 10°C GELTRACE-35 Self Limiting cable, 35m lenght, with 5°C thermostat, 1m cold lead 450 W à 10°C
DATASHEET
Nominal Voltage 230V Maximum length circuit: GELTRACE-35…………. 35 m Tolérances sur la puissance -0/+5 W Maximum exposure temperature (energised) 65°C Maximum exposure temperature (deenergised) 80°C Temperature Class T6 Minimum Bending Radius 27 mm Minimum installation temperature -35°C Weight approx 66 kg/km
QUALIFICATIONS
Certifications CE

Last Updated on Tuesday, 03 May 2011 19:47
HIGH TEMPERATURE SELF LIMITING HEATING CABLE
ESR®-H-BOT
HIGH TEMPERATURE HEATING CABLE (120°C / 200°C) FOR PIPE, TANK, CORROSIVE ATMOSPHERE..
The ESR®-H-BOT serie is a self-limiting heating tape that is suitable for freeze protection and for temperature maintenance in applications up to 120 ºC.
It allows steam cleaning in pipes. The heating element, the insulation and the outer jacket of the ESR-H-BOT are made of fluoropolymers.
The Fluoropolymer is Used as an outer jacket, this material offers increased protection against chemicals and abrasion.
The heating power of the conductive heating element increases or decreases depending on the ambient temperature. The self-limitation takes effect at every point along the heating tape. The heating power adapts to the varying ambient temperatures.
DESCRIPTION
1- Copper, nickel-coated 1.25 mm2 2– Heating element : Conductive fluoropolymer 3– Fluoropolymer 4- Braid 5– Fluoropolymer Overjacket
Référence Désignation Puissance Section totale ESR-H-BOT-10 ESR-H-2-BOT-10 10 W/m à 10°C 10,20 x 4,80 (mm) ESR-H-BOT-15 ESR-H-2-BOT-15 15 W/m à 10°C 10,20 x 4,80 (mm) ESR-H-BOT-30 ESR-H-2-BOT-30 30 W/m à 10°C 10,20 x 4,80 (mm) ESR-H-BOT-45 ESR-H-2-BOT-45 45 W/m à 10°C 10,20 x 4,80 (mm) ESR-H-BOT-60 ESR-H-2-BOT-60 60 W/m à 10°C 10,20 x 4,80 (mm)
HEATING CABLE DATASHEET
Nominal Voltage 230V
Tolerances -2.5/+2.5 W
Maximum exposure temperature (energised) 120°C
Maximum exposure temperature (deenergised) 200°C
Temperature Class T3 (T2 for 60w/m)
Minimum Bending Radius 25 mm
Minimum installation temperature -40°C Weight approx 120 kg/km
Maximum length circuit:
ESR-H-2-BOT-10………….. 205 m ESR-H-2-BOT-15………….. 165 m ESR-H-2-BOT-30………….. 115 m ESR-H-2-BOT-45………….. 85 m ESR-H-2-BOT-60………….. 65 m
PRODUITS QUALIFICATIONS
Certifications CSTB, ATEX, VDE, GOST-R, CE
   
Last Updated on Tuesday, 03 May 2011 19:48
|